You have no items in your shopping cart.
Details
T-55 Automatic Adaptive Core Fusion Splicer
Fast, Capable, Practical
Fast Splicing 7 sec / Heating 20sec
Detachable Case
for Working Tray
Touch Screen Control Panel
Durable & Rugged
Specification
Applicable optical fiber | Material | Silica Glass |
---|---|---|
Profile type | Single Mode Fiber (SMF)/ITU-T G652 Multi Mode Fiber (MMF)/ITU-T G651 Dispersion Shifted Fiber (DSF)/ITU-T G653 Non-Zero Dispersion Shifted Fiber (NZ-DSF)/ITU-T G655, G656 Bend Insensitive Fiber (BIF)/ITU-T G657 |
|
Number of fiber | Single | |
Cladding diameter | φ80 to φ150 μm *1 | |
Coating diameter | φ100 to φ1,000 μm | |
Cleave length |
5 to 16 mm (with coating clamp) 10mm (Drop cable / Indoor cable with fiber holder) |
|
Applicable Cable*2*3 | 0.25 mm primary coated 1-fiber drop cable | 3.1mm or 2.6mm×2.0mm (excluding messenger steel wire) |
0.25 mm primary coated 1-fiber indoor cable | 2.0mm×1.6mm | |
Splice Performance | Splice loss (typical)*4 | SMF : 0.02 dB MMF: 0.01 dB DSF : 0.04 dB NZDSF : 0.04 dB |
Return loss (typical) | 60dB or greater | |
Screening load (typical) | 1.96N - 2.09N (at stage) | |
Splice time (typical) |
Approx. 7 seconds (SM G652 Quick Mode) Approx. 9 seconds (Auto Mode) |
|
Automatic fiber identification | SMF / MMF / Other | |
Splice & Heat cycles*5 | Approx. 115 cycles (BU-11S) | |
Fiber view & magnification | 2 CMOS cameras observation, 200X (zoom : 525X) for X or Y single axis view, 88X for X & Y dual axis view |
|
Splice program | Maximum 300 splice programs can be selected and customized. | |
Splice data storage | 10,000 splices | |
Splice image capture | 200 splices | |
Fiber Alignment method | Adaptive Core | Aligns the left and right fibers by the center of their cores, or by the logical center of their cores in case of complicated core profiles. |
Diameter | Aligns the left and right fibers by their outer diameter. | |
ATTN | “Attenuation”. Fibers are spliced by shifting the centers of the left and right fiber cores to achieve intentional high splice losses. | |
Heater Performance | The number of heaters | Single |
Sleeve length | Up to 60mm | |
Protection sleeve *6 | The protection sleeve for single fiber, up to 60mm length, up to φ5mm diameter. e.g. FPS-1 (single, 60mm, Cleave length 5-16mm) FPS-61-2.6 (thin, single, 60mm, Cleave length 5-16mm) FPS-40 (single, 40mm, Cleave length 5-10mm) FPS-40-2.6 (thin, single, 40mm, Cleave length 5-10mm) |
|
Heating time(typical) *7 | Approx. 20 seconds (Slim 60mm 0.25 Mode) | |
Program | Max. 100 settings | |
Physical Characteristics | Size (Main body) *8 | 120W×154D×130H(mm) |
Weight | Approx. 1.9 kg (With Battery pack BU-11S) | |
Display size | 4.1" touch screen color LCD display | |
V-groove illumination | White LED | |
Power Conditions | Power consumption | Max. 110W |
AC operation |
With AC adapter ADC-1430 series Input: AC 100-240V 50/60Hz 1.1A |
|
DC operation | Input: DC 10-15V, 7.5A | |
Battery operation | (With BU-11S) 11.1V (2300mAh) | |
DC output | 12V For Sumitomo’s hot jacket remover | |
In - Out Terminal | Serial port | USB 2.0 mini-B type |
Storage media | SD / SDHC memory card | |
Environmental Conditions | Operating temperature | -10 to +50°C |
Storage temperature | -40 to +80°C | |
Humidity | 0 to 95%RH with no dew present | |
Altitude | Up to 6,000 m | |
Environmental Durability*9 | Shock resistance | Drop from 76cm on 5 faces (Excluding top face) |
Water resistance | Equivalent to IPx2 (Operates normally after being exposed to water dripping at 3mm/min. for at least 2.5 min on each of 4 surfaces tilted at 15 degree.) | |
Dust resistance | Equivalent to IPx5 (Operates normally after 8 hours in a dust chamber containing dust of particle size 75 um or below) |
*2 Fiber holders appropriate for the fiber coating and fiber count are required.
*3 These fiber holders cannot be used with loose tube cable which optical fiber is free to move about in.
*4 Average value of the final inspection in room temperature with Sumitomo identical fiber. Measured by cut-back method relevant to ITU-T and IEC standards.
*5 Splice & Heat cycles may vary depending on the battery status and the operating environment.
*6 The 40mm protection sleeves can be used only if the cleave length is less than 10mm. Do not use the 40mm protection sleeves for fibers with more than φ250μm coatings.
*7 With Sumitomo protection sleeve FPS-61-2.6, Coating diameter φ250μm (in room temperature, powered with AC adapter, DC output port not in use)
*8 The projection parts are excluded.
*9 Confirms the battery operation in tests carried out by Sumitomo. Does not guarantee that the product is free of faults or damage.